The pressure-reduction system controls the supply pressure to the gas users at a regulated value. Each system consists of at least two trains of pressure reduction – one operating and the other standby. Each train will normally comprise two regulator valves in series.
Regulator valves should be sized for the maximum anticipated volumes at the minimum anticipated inlet pressure during those times of maximum volume. For stations serving multiple residential customers or other non-interruptible services, sufficient regulator capacity needs to be provided so the failure of one regulator valve run will not reduce the facility capacity below required demand. Regulator valves in custody transfer stations are typically of the type that fail in the open position.